22
GENERAL OPERATING INFORMATION
Rated Capacity
3,500 gal. for Aesthetic Chlorine / 243 gal. for VOC’s
Min-Max operating pressure:
40psi-120psi (275Kpa-827Kpa)
Min-Max feed water temperature:
41°F – 95°F (5°C – 35°C)
Rated Service Flow
0.07 gallons per minute
Daily Water Production Rate
56.9 gallons per day
Product Efficiency Rating
30.6%
• Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection
before or after the system.
• Refer to the owners manual for specific installation instructions, manufacturer’s limited warranty, user
responsibility, and parts and service availability.
• The influent water to the system shall include the following characteristics:
• No organic solvents
• Chlorine: < 2 mg/L
• pH: 7 - 8
• Temperature: 41 ~ 95 ºF (5 ~ 35 ºC)
• Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.
• Iron: < 2 mg/L
• Turbidity: < 1 NTU
• Hardness: < 1 000 mg/L
Substance
Influent Challenge
Concentration
(mg/L unless specified)
Maximum Allowable Product
Water Concentration
(mg/L unless specified)
Percent Reduction
(%)
Arsenic (Pentavalent) 0.05 +/- 10% 0.01 98.9
Barium 10.0 +/- 10% 2 98.2
Radium 226/228 25 pCi/L 5 pCi/L 80
Cadmium 0.03 +/- 10% 0.005 98.2
Chromium (Hexavalent) 0.3 +/- 10% 0.1 97.3
Chromium (Trivalent) 0.3 +/- 10% 0.1 97.8
Copper 3.0 +/- 10% 1.3 98.7
Lead 0.15 +/- 10% 0.01 98.2
Selenium 0.10 +/- 10% 0.05 97.3
Fluoride 8.0 +/- 10% 1.5 83.8
TDS 750 +/- 40 187 92.5
Aesthetic Chlorine 2.0 +/- 10 % >/= 50% Reduction 98.4
VOCs 0.300 +/- 10% >/= 95% Reduction 99.8
While testing was performed under laboratory conditions, actual performance may vary.
The RC100 is tested and certified to NSF/ANSI 42, 53 and 58 for the reduction of Aesthetic Chlorine,
Taste and Odor, Cyst*, VOCs, Fluoride, Pentavalent Arsenic, Barium, Radium 226/228, Cadmium,
Hexavalent Chromium, Trivalent Chromium, Lead, Copper, Selenium and TDS as verified and
substantiated by test data. The RC100 conforms to NSF/ANSI 372 for low lead compliance.
*NSF/ANSI 58 Cyst reduction of 99.9% based on independent testing not certified by WQA.
This system has been tested according to NSF/ANSI 42, 53 and 58 for the reduction of the substances
listed below. The concentration of the indicated substances in water entering the system was
reduced to a concentration less than or equal to the permissible for water leaving the system, as
specified in NSF/ANSI 42, 53 and 58.
CIRCLE FILTRATION SYSTEM PERFORMANCE DATA SHEET
Model: RC100